491

DEVELOPMENT OF AN IN VITRO CORROSION/IRRITATION PREDICTION ASSAY USING THE EPIDERM™ SKIN MODEL.

Kidd1,2, D.A., Johnson1, M., Clements1, J. 1Department of Genetic and Molecular Toxicology, Covance Laboratories Ltd., Otley Road, Harrogate, North Yorkshire HG3 1PY, UK. 2Department of Biology, University of York, Heslington, York, North Yorkshire YO1 7EP, UK.
Abstract

This study by scientists at Covance Laboratories and the University of York demonstrated that MatTek’s EpiDerm in vitro human skin tissue equivalent can be used to accurately predict the dermal corrosivity and skin irritation potential of 12 test chemicals. A validation of the in vitro skin corrosion method using the EpiDerm™ skin model was performed using 12 recommended chemicals. All chemicals were correctly classified by OECD test guideline 431. In order to predict corrosion and/or irritation potential, additional compound exposure times and IL-1á measurements were included in a tiered testing approach. Four exposure times were performed followed by MTT (viability) and IL-1á measurement. This allowed classification of corrosive chemicals (OECD guideline 431) and those likely to be severe irritants. If the chemical was found to be corrosive or a severe irritant, no further experimental work was performed, otherwise a second experiment was performed using three further exposure times (same endpoints). The second experiment provided information on whether the chemical was likely to be a moderate/mild irritant. If the chemical was negative following both experiments, it was predicted as non-corrosive/non-irritating. A total of 12 chemicals were tested in the irritation or combined assay (five non-irritants, seven irritants). Specificity (% non-irritants concurring with EU classification) was 60% (MTT) and 100% (MTT + IL-1á). Sensitivity (% irritants concurring with EU classification) was 86% (MTT) and 86% (MTT + IL-1á). Accuracy (% chemicals correctly identified) was 75% (MTT) and 92% (MTT + IL-1á).

Keywords

EpiDerm, IL-1a, Irritation prediction assay, MTT, Moderate/mild irritant, OECD test guideline 431, Skin corrosion, Skin irritancy, Skin irritation

Materials Tested

(2-Bromoethyl)benzene, 1% (v/v) SDS, 1% (v/v) Triton X-100, 1,1,1-Trichloroethane, 1,2-Diaminopropane, 1,6-Dibromohexane, 1,9-Decadine, 1-Bromopentane, 10% (v/v) Tween 20, 2,4-Xylidine, 2-tert-Butylphenol, 4-(Methyl-thio)-benzaldehyde, 4-Amino-1,2,4-triazole, 4-Amino-1,2,4-triazole, Acrylic acid, Eugenol, Heptanal, Hydroxycitronellal, Methyl palmitate, N-Heptylamine, Octanoic acid, Sulphuric acid, Tetrachloroethylene

Request a copy of this paper, click here.