REGULATORY REQUIREMENTS FOR IN VITRO SYSTEMS TO MEET PERFORMANCE STANDARDS OVER TIME AS WELL AS DURING VALIDATION.

Klausner, M., Kubilus, J., Ayehunie, S., Hayden, P., Chua, G., Sheasgreen, J. MatTek Corporation, Ashland, MA 01721.
Abstract

This technical poster by scientists at MatTek Corp. summarized 12-PLUS YEARS (1996-2007) of commercial production QC data for MatTek’s EpiDerm and EpiOcular in vitro human tissue equivalents, and how that data addresses regulatory concerns regarding performance standards of alternative in vitro testing methods over time. In vitro models are being proposed as alternatives to animal testing for safety evaluation of cosmetics, pharmaceuticals and consumer products. Currently available MatTek organotypic human models include dermal (EpiDerm, EpiDerm-FT), ocular (EpiOcular), ectocervical (EpiVaginal) and airway (EpiAirway). Some of these models have been, or are in the process of being, formally validated for testing of corrosivity, irritation or toxicity. However, regulatory agencies and other users also need to be reassured that the models will provide consistent, good quality data over time, not just during the validation process (K. Gupta et al., Regul Toxicol Pharmacol. 2005 Dec;43(3):219-24). Recommended guidelines include “full characterization of cells or tissues, sampling of each lot … for performance, and regular use of controls and benchmark chemicals to provide assurance of consistency of assay performance” (A. Rispin et al. Regul Toxicol Pharmacol. 2006 Jul;45(2):97-103). This MatTek poster summarizes the long-term reproducibility and performance of in vitro epidermal (EpiDerm) and ocular (EpiOcular) models against benchmark chemical treatment. Quality control of weekly batches of EpiDerm and EpiOcular was performed using the MTT assay. The exposure time needed to reduce the viability to 50% (ET-50) for Triton X-100 was determined. For EpiOcular, the yearly average ET-50 values have ranged from 20.6 minutes to 25.0 minutes. The coefficients of variation (CV) for the negative control tissue (exposed to ultrapure H2O) have averaged under 6% for every year since 1997. In addition, the yearly average CV for all tissues has never exceeded 6.5%. For EpiDerm, the yearly average ET-50 values have ranged from 6.0 hrs to 7.5 hrs. The coefficients of variation (CV) for the negative control tissue (exposed to ultrapure H2O) have averaged under 7.5% for every year since 1996. These results for MatTek’s EpiDerm and EpiOcular tissue models over the past 10 years of commercial production are designed to address regulatory concerns regarding performance standards over time.

Keywords

Assays, ET-50, Histology, MTT

Materials Tested

Assays, ET-50, Histology, MTT

Request a copy of this paper, click here.